• Login
    View Item 
    •   DSpace Home
    • FACULTY OF EXPLORATION AND PRODUCTION TECHNOLOGY
    • PETROLEUM ENGINEERING (TEKNIK PERMINYAKAN)
    • DISSERTATIONS AND THESES (PE)
    • View Item
    •   DSpace Home
    • FACULTY OF EXPLORATION AND PRODUCTION TECHNOLOGY
    • PETROLEUM ENGINEERING (TEKNIK PERMINYAKAN)
    • DISSERTATIONS AND THESES (PE)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    OPTIMIZING THE USE OF LCM (LOST CIRCULATION MATERIALS) TO MITIGATE LOSSES IN WELL-X

    Thumbnail
    View/Open
    LAPORAN TUGAS AKHIR (5.764Mb)
    Date
    2024-08-13
    Author
    Romadhoni, Rafi Rizki
    Metadata
    Show full item record
    Abstract
    Drilling in the oil and gas industry brings a diverse range challenges that consume time and precious resources. Wellbore instability-related issues account for 40% of Non-Productive Time (NPT) during oil and gas well drilling, including loss circulation, pinched pipe, uncontrolled flow, kick, shale sloughing, and wellbore collapse. Lost circulation is one of the biggest headwinds, contributing significantly to NPT. Lost Circulation Materials (LCM) are rapidly emerging as an effective solution to solve this problem. This research involved laboratory testing of various concentrations of LCM, including Granular LCM (CaCO3 F/M/C, PF-NUT F), Fibrous LCM (PF-FRACSEAL F/M, QUICKSEAL C), and a combination of both. Tests using Particle Size Distribution (PSD) Laser Diffraction, Particle Size Distribution (PSD) Sieve Screen Shaker, and Permeability Plugging Apparatus with 20 and 35 micron ceramic discs to address seepage to partial losses, and 2540 and 5000 micron slotted discs to address severe to major/total losses in Well-X. The research results show that the use of a combination of Fibrous and Granular LCM in the Background LCM (BGLCM) formulation is effective in dealing with Seepage-Partial Losses, and LCM Pills are effective in dealing with Severe-Total Losses, showing MET SPEC results that are able to plug up flow of fluid through fractures and rock pores. The concentration and distribution of particles affect the effectiveness of LCM formulations. High concentrations give better results on a laboratory scale, while varying particle sizes are required for optimal effectiveness in the field. The research also evaluated the cost-effectiveness of using LCM, finding effective BGLCM and LCM Pills formulations at varying costs depending on the type of circulation losses being addressed.
    URI
    https://library.universitaspertamina.ac.id//xmlui/handle/123456789/12591
    Collections
    • DISSERTATIONS AND THESES (PE)

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV