    PERBANDINGAN PERANCANGAN STRUKTUR GEDUNG TAHAN GEMPA BERDASARKAN SNI 1726-2012 DAN SNI 2847-2013 DENGAN SNI 1726-2019 DAN SNI 2847-2019. Studi Kasus : Gedung Apartement Student Universitas Islam Internasional Indonesia (UIII) Depok

    Thumbnail
    View/Open
    Laporan Tugas Akhir(Repository)_Khansa Mayska Yasir_104116041.pdf (4.092Mb)
    Date
    2021-02-21
    Metadata
    Show full item record
    Abstract
    This design is about the comparison of the building design based on SNI 1726-2012 and SNI 2847-2013 with the latest SNI 1726-2019 and SNI 2847-2019 standards to know the differences in applicable regulations, especially the dimensional differences in column and beam cross-sections. The method used is a literature study and analysis using the SAP 2000 vs. 22 programs and verified by manual calculations on Microsoft Excel. The results showed that the building design according to SNI 2847-2013 and SNI 2847-2019 did not change much because the structural system used was still the same, namely SRPMK in the main structure. The biggest difference is caused by the latest standard of the earthquake, namely SNI 1726-2019, where with that standard many changes in the value of the earthquake coefficient, resulting in a larger structural base shear force. The greater of the shear force, making the cross-sectional dimensions of beams and columns must have been enlarged. The dimensions of the beam designed with the latest standard reached most 78% of the previous standard. Meanwhile, the dimensions of the column must be enlarged to reach 50% of the original dimension. This affects the diameter and the amount of reinforcement which must also have been enlarged. Keywords: The Previous Standard, The Latest Standard, Structural System, Sectional Dimensions, Cross-section Reinforcement
    URI
    https://library.universitaspertamina.ac.id//xmlui/handle/123456789/3521
    Collections
    • DISSERTATIONS AND THESES (CV)

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV